B1973–POWER LIFTGATE OPEN DIRECTION – RATCHET SECONDARY SWITCH PERFORMANCE





For a complete wiring diagram Refer to Section 8W


  • When Monitored:

    Whenever the power liftgate is performing a power opening operation.

  • Set Condition:

    The ratchet switch is detected as open when the Power Liftgate Drive Unit position count is greater than 90.


Possible Causes
 
(Q901) LOGIC GROUND CIRCUIT OPEN
 
(Q76) LATCH SECONDARY POSITION SENSE CIRCUIT OPEN
 
(Q76) LATCH SECONDARY POSITION SENSE CIRCUIT SHORT TO VOLTAGE
 
POWER LIFTGATE LATCH
 
POWER LIFTGATE MODULE
 




Diagnostic Test

1.DTC PRESENT

NOTE: This DTC will only set during the releasing operation after the four second time out. This may make it difficult to reproduce.







Does the scan tool display B1973–POWER LIFTGATE OPEN OPERATION- RATCHET SECONDARY SWITCH PERFORMANCE?

Yes
  • Go To2


No

2.BINDING LIFTGATE






Does it take more effort to operate the liftgate than it should?

Yes


No
  • Go To 3

3.POWER LIFTGATE MODULE






Did the scan tool show the switch state changing correctly every time?

No
  • Go To4


Yes

4.CHECK THE (Q901) LOGIC GROUND CIRCUIT FOR AN OPEN








Is the resistance below 9.5 ohms?

Yes
  • Go To5


No

5.CHECK THE (Q76) LATCH SECONDARY POSITION SENSE CIRCUIT OPEN







Is the resistance below 2.0 ohms?

No


Yes
  • Go to 6

6.(Q76) LATCH SECONDARY POSITION SENSE CIRCUIT SHORT TO VOLTAGE







Is there any voltage present?

No


Yes