B196D–POWER LIFTGATE OPEN DIRECTION – FULL OPEN SWITCH PERFORMANCE





For a complete wiring diagram Refer to Section 8W


  • When Monitored:

    During the Power Liftgate open cycle or liftgate fully closed prior to activation.

  • Set Condition:

    The Power Liftgate Drive Unit Full Open Switch was detected as closed with the liftgate being fully closed or the latch being fully latched.

    The Power Liftgate Drive Unit Full Open Switch was detected as closed before 820 pulses of the Power Liftgate Drive Unit position sensor were counted since the start of the open operation.

    The Power Liftgate Drive Unit Full Open Switch remained open after approximately 860 pulses of the Power Liftgate Drive Unit position sensor were counted since the start of the open operation.

    May be triggered by an intermittent full open switch failure.


Possible Causes
 
LATCH HAS BEEN MANUALLY LATCHED WITH THE GATE IN THE FULL OPEN POSITION
 
(Q51) LIFTGATE FULL OPEN SWITCH SENSE CIRCUIT OPEN
 
(Q51) LIFTGATE FULL OPEN SWITCH SENSE CIRCUIT INTERMITTENT SHORT TO GROUND
 
(Q51) LIFTGATE FULL OPEN SWITCH SENSE CIRCUIT SHORT TO GROUND
 
(Q901) LOGIC GROUND OPEN
 
POWER LIFTGATE DRIVE UNIT
 
POWER LIFTGATE MODULE
 




Diagnostic Test

1.DTC PRESENT







Does the scan tool display B196D–POWER LIFTGATE OPEN DIRECTION – FULL OPEN SWITCH PERFORMANCE?

Yes
  • Go To2


No

2.OBSTRUCTION OR STICKING SWITCH





Does the switch status change smoothly as the liftgate is pulled down from the full open position?

Yes
  • Go To3


No
  • Go To4

3.(Q51) FULL OPEN SWITCH SENSE CIRCUIT INTERMITTENT SHORT TO GROUND

CAUTION: Never operate the Power Liftgate Drive Unit with the link rod removed as it could damage the Drive Unit.









Did the switch status ever change?

Yes


No

4.POWER LIFTGATE DRIVE UNIT – FULL OPEN SWITCH







Is the voltage constantly above 4.6 volts?

Yes


No
  • Go To6

5.(Q51) LIFTGATE FULL OPEN SWITCH SENSE CIRCUIT SHORT TO GROUND







Is the resistance below 1000.0 ohms?

Yes


No
  • Go To 6

6.(Q51) LIFTGATE FULL OPEN SWITCH SENSE CIRCUIT SHORT TO (Q901) LOGIC GROUND





Is the resistance below 1000.0 ohms?

Yes


No
  • Go To 7

7.(Q901) LOGIC GROUND OPEN







Is the resistance below 9.5 ohms?

Yes
  • Go To 8


No

8.(Q51) LIFTGATE FULL OPEN SWITCH SENSE CIRCUIT OPEN






Is the resistance below 5.0 ohms?

No


Yes