B196C–POWER LIFTGATE CLOSE DIRECTION EXCESSIVE POSITION SENSOR COUNTS





For a complete wiring diagram Refer to Section 8W


  • When Monitored:

    During Power Liftgate closing cycle.

  • Set Condition:

    If the Power Liftgate Module detects that the Power Liftgate Drive Unit has generated excessive pulses during a full power cycle, this code will set.


Possible Causes
 
(Q901) LOGIC GROUND CIRCUIT OPEN
 
POWER LIFTGATE DRIVE UNIT
 
POWER LIFTGATE MODULE
 




Diagnostic Test

1.DTC PRESENT






Does the scan tool display B196C–POWER LIFTGATE CLOSE DIRECTION EXCESSIVE POSITION SENSOR COUNTS?

Yes
  • Go To 2


No

2.BINDING LIFTGATE




Were there any mechanical problems found?

Yes


No
  • Go To 3

3.POWER LIFTGATE MODULE - POSITION SENSE OPEN



Did the liftgate reverse back to the closed position?

Yes
  • Go To 4


No

4.(Q901) LOGIC GROUND OPEN





Is the resistance below 9.5 ohms?

Yes
  • Go To 5


No

5.POWER LIFTGATE DRIVE UNIT




Does the motor start to lift the liftgate but moves very slow and labors extensively?

Yes


No