B1967–POWER LIFTGATE OPEN DIRECTION OVERCURRENT

For a complete wiring diagram Refer to Section 8W


  • When Monitored:

    Anytime the Power Liftgate is in a power open operation.

  • Set Condition:

    The drive motor stall current of over 24 amps has been detected for over 500 ms. during the power opening operation.


Possible Causes
 
BINDING LIFTGATE OR OVERLOADING
 
(Z800) GROUND CIRCUIT OPEN
 
(Q84) LIFTGATE LATCH CINCH DRIVER CIRCUIT SHORT TO (Q901) LOGIC GROUND
 
(Q88) LIFTGATE OPEN DRIVER CIRCUIT SHORT TO GROUND
 
(Q201) LIFTGATE CLUTCH DRIVER CIRCUIT SHORT TO GROUND
 
POWER LIFTGATE MODULE
 
POWER LIFTGATE DRIVE UNIT
 




Diagnostic Test

1.DTC PRESENT






Does the scan tool display B1967–POWER LIFTGATE OPEN DIRECTION OVERCURRENT?

Yes
  • Go To2


No

2.BINDING LIFTGATE





Were there any mechanical problems found?

Yes


No
  • Go To3

3.POWER LIFTGATE DRIVE UNIT




Does the motor start to lift the liftgate but is very slow and labors extensively?

Yes


No