B1952–POWER LIFTGATE DRIVE MOTOR – INCORRECT DIRECTION





For a complete wiring diagram Refer to Section 8W


  • When Monitored:

    Whenever the Power Liftgate Motor is in operation.

  • Set Condition:

    When the Power Liftgate Module senses the direction of the drive motor is in opposition to the direction it is trying to drive the liftgate, this code will set.


Possible Causes
 
(Q88) LIFTGATE OPEN DRIVER CIRCUIT SHORTED TO THE (Q89) LIFTGATE CLOSE DRIVER CIRCUIT
 
(Q204) POSITION SENSOR SIGNAL 1 CIRCUIT SHORTED TO THE (Q205) POSITION SENSOR SIGNAL 2 CIRCUIT
 
(Q204) POSITION SENSOR SIGNAL 1 SHORT TO GROUND
 
(Q204) POSITION SENSOR SIGNAL 1 SHORT TO VOLTAGE
 
(Q204) POSITION SENSOR SIGNAL 1 OPEN
 
POWER LIFTGATE DRIVE UNIT
 
POWER LIFTGATE MODULE
 




Diagnostic Test

1.DTC PRESENT







Does the scan tool display B1952–POWER LIFTGATE DRIVE MOTOR – INCORRECT DIRECTION?

Yes
  • Go To 2


No

2.(Q204) POSITION SENSOR SIGNAL 1 CIRCUIT SHORT TO GROUND






Is the resistance below 10000.0 ohms?

Yes


No
  • Go To 3

3.(Q204) POSITION SENSOR SIGNAL 1 CIRCUIT SHORT TO VOLTAGE






Is there any voltage present?

Yes


No
  • Go To 4

4.(Q204) POSITION SENSOR SIGNAL 1 CIRCUIT OPEN






Is the resistance below 5.0 ohms?

No


Yes
  • Go To 5

5.CHECK THE (Q88) LIFTGATE OPEN DRIVER CIRCUIT AND THE (Q89) LIFTGATE CLOSE DRIVER CIRCUITS FOR A SHORT TOGETHER








Is the resistance below 1000 ohms?

No
  • Go To 6


Yes

6.CHECK (Q204) POSITION SENSOR SIGNAL 1 AND THE (Q205) POSITION SENSOR SIGNAL 2 CIRCUITS FOR A SHORT TOGETHER





Are the circuits shorted at either connector?

No


Yes