B188E–POWER LIFTGATE CONTROL CIRCUIT 1 HIGH





For a complete wiring diagram Refer to Section 8W


  • When Monitored:

    Whenever the Power Liftgate is power opening or closing.

  • Set Condition:

    When the Power Liftgate Module senses voltage more than 9.5 volts on the (Q88) Liftgate Open Driver circuit prior to starting a liftgate power open or close cycle, this code will set.


Possible Causes
 
(Q88) LIFTGATE OPEN DRIVER CIRCUIT SHORT TO VOLTAGE
 
(Q89) LIFTGATE CLOSE DRIVER CIRCUIT SHORT TO VOLTAGE
 
(Q88) LIFTGATE OPEN DRIVER CIRCUIT SHORT TO (Q89) LIFTGATE CLOSE DRIVER CIRCUIT
 
POWER LIFTGATE DRIVE UNIT
 
POWER LIFTGATE MODULE
 




Diagnostic Test

1.DTC PRESENT







Does the scan tool display B188E–POWER LIFTGATE CONTROL CIRCUIT 1 HIGH?

Yes
  • Go To 2


No

2.(Q88) LIFTGATE OPEN DRIVER CIRCUIT SHORT TO VOLTAGE









Is there any voltage present?

Yes


No
  • Go To 3

3.(Q89) LIFTGATE CLOSE DRIVER CIRCUIT SHORT TO VOLTAGE





Is there any voltage present?

Yes


No
  • Go To 4

4.(Q88) LIFTGATE OPEN DRIVER CIRCUIT SHORT TO (Q89) LIFTGATE CLOSE DRIVER CIRCUIT






Is the resistance below 10000.0 ohms?

No


Yes
  • Repair the (Q88) Liftgate Open Driver circuit for a short to the (Q89) Liftgate Close Driver circuit. If the (Q88) Liftgate Open Driver circuit and the (Q89) Liftgate Close Driver circuits are OK, replace the Power Liftgate Drive Unit in accordance with the service information.
  • Perform BODY VERIFICATION TEST - VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE).