P2116-ACCELERATOR PEDAL POSITION SENSOR 2 MINIMUM STOP PERFORMANCE

For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    Ignition on. During in plant mode the APP Sensors need to be checked to make sure that idle and full pedal travel can be reached on both sensors. The test for P2116 is only enabled once test for P2167 has passed.

  • Set Condition:

    APPS No.2 has failed to achieve the required minimum value during In Plant testing. One trip fault and the code will be stored within 5 seconds. Engine will only idle. ETC light is illuminated.


Possible Causes
 
IN PLANT TEST FAILURE
 
APPS RELEARN
 


Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. (Refer to 9 - ENGINE - DIAGNOSIS AND TESTING).



Diagnostic Test

1.IN PLANT TEST FAILURE


NOTE: This DTC is set when the APP Sensors are learned in plant but do not reach the Minimum or Maximum voltage range.







Is the DTC Active at this time?

Yes
  • Go To 2


No

2.APPS RELEARN





Does the DTC return?

Yes
  • Replace the APPS Assembly per Service Information. After installation is complete, use a scan tool and select the ETC RELEARN function.
  • Perform the POWERTRAIN VERIFICATION TEST. (Refer to 9 - ENGINE - STANDARD PROCEDURE)


No
  • Test Complete.