B1083–HVAC MUX CIRCUIT HIGH





For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    With the ignition on.

  • Set Condition:

    If the Instrument Cluster (CCN) detects voltage above 4.5 volts for 10 seconds on the (C221) A/C Switch Sense circuit.


Possible Causes
 
(C221) A/C SWITCH SENSE CIRCUIT SHORTED TO VOLTAGE
 
(C221) A/C SWITCH SENSE CIRCUIT OPEN
 
INSTRUMENT CLUSTER (CCN)
 
A/C HEATER CONTROL
 




Diagnostic Test

1.VERIFY DTC B1083–HVAC MUX CIRCUIT HIGH IS ACTIVE






Does the scan tool display active: B1083–HVAC MUX CIRCUIT HIGH?

Yes
  • Go To 2


No

2.CHECK (C221) A/C SWITCH SENSE CIRCUIT VOLTAGE AT A/C HEATER CONTROL C1 HARNESS CONNECTOR








What is the voltage?

Below 4.8 Volts
  • Go To 3


4.8 to 5.2 Volts


Above 5.2 Volts
  • Go To 4

3.CHECK (C221) A/C SWITCH SENSE CIRCUIT FOR AN OPEN







Is the resistance below 5.0 ohms?

Yes


No

4.CHECK (C221) A/C SWITCH SENSE CIRCUIT FOR A SHORT TO VOLTAGE








Is the voltage above 0.2 volts?

Yes


No