42–SECOND ROW MODE OVERCURRENT (MTC)





For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    When actuator movement is requested.

  • Set Condition:

    If the A/C Heater Control detects an excessive current draw on any of the door driver circuits while attempting to drive this door actuator. Note that only one overcurrent DTC can set per ignition cycle.


Possible Causes
 
DOOR DRIVER CIRCUIT(S) SHORTED TO VOLTAGE
 
DOOR DRIVER CIRCUIT(S) SHORTED TO GROUND
 
DOOR DRIVER CIRCUITS SHORTED TOGETHER
 
FRONT MODE DOOR ACTUATOR
 
SECOND ROW MODE DOOR ACTUATOR
 
LEFT BLEND DOOR ACTUATOR
 
RECIRCULATION DOOR ACTUATOR
 
A/C HEATER CONTROL
 


NOTE: This DTC must be active for the result of this test to be valid. Do not perform this test if this DTC is stored. Refer to HVAC System Test (MTC) for stored DTC test procedures.



Diagnostic Test

1.RUN THE ACTUATOR CIRCUIT TEST / DOOR CALIBRATION FUNCTION & THEN CHECK FOR ACTUATOR CIRCUIT TEST FAULTS

NOTE: Diagnose and repair Actuator Circuit Test faults (DTC 61, 62, 63, 64, 65, 66, 67, 68, 69, 71, and 72) before diagnosing Overcurrent faults (DTC 41, 42, 43, and 44).



  • Turn the blower control on.
  • Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately 5 seconds) and then release the A/C mode switch.
  • When the A/C status indicator begins displaying DTCs, set the Mode switch to the floor position, simultaneously press the A/C mode switch and the EBL mode switch down until both LEDs start flashing (approximately 5 seconds) and then release the mode switches. Stored DTCs will clear from memory in approximately two seconds.


  • Turn the blower control off.
  • Press and hold the EBL mode switch down and then turn the blower control on. Continue to hold the EBL mode switch down until the EBL status indicator begins flashing. Then, release the EBL mode switch. While the test / function is running, the EBL status indicator will flash once per second. If the test / function passes, the EBL status indicator will stop flashing. If the test / function fails, the A/C and EBL status indicators will flash alternately. Allow the test / function to run to completion before proceeding.

  • Turn the blower control on.
  • Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately 5 seconds) and then release the A/C mode switch.

NOTE: The A/C status indicator displays active DTCs when the EBL status indicator is not illuminated and stored DTCs when the EBL status indicator is illuminated.




Does the A/C status indicator display any of the following DTCs: 61, 62, 63, 64, 65, 66, 67, 68, 69, 71, or 72?

Yes
  • As present, diagnose and repair the Actuator Circuit Test faults in the following order: DTC 72 first, then DTC 62, then DTC 61, then DTCs 64, 66, 68, or 71, and finally DTCs 63, 65, 67, or 69. Refer to the Table Of Contents in this section for a complete list of HVAC related symptoms.
  • Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE).


No
  • Go To2

2.CHECK THE (C266) FRONT MODE DOOR DRIVER CIRCUIT FOR A SHORT TO THE (C139) SECOND ROW MODE DOOR DRIVER CIRCUIT, (C939) SECOND ROW MODE DOOR COMMON DRIVER CIRCUIT, (C255) LEFT BLEND DOOR DRIVER CIRCUIT, (C55) LEFT BLEND DOOR COMMON DRIVER CIRCUIT, (C268) RECIRCULATION DOOR DRIVER CIRCUIT, & THE (C68) RECIRCULATION DOOR COMMON DRIVER CIRCUIT







Is the resistance below 10k ohms on any of the circuits?

Yes


No
  • Go To3

3.CHECK THE (C66) FRONT MODE DOOR COMMON DRIVER CIRCUIT FOR A SHORT TO THE (C139) SECOND ROW MODE DOOR DRIVER CIRCUIT, (C939) SECOND ROW MODE DOOR COMMON DRIVER CIRCUIT, (C255) LEFT BLEND DOOR DRIVER CIRCUIT, (C55) LEFT BLEND DOOR COMMON DRIVER CIRCUIT, (C268) RECIRCULATION DOOR DRIVER CIRCUIT, & THE (C68) RECIRCULATION DOOR COMMON DRIVER CIRCUIT





Is the resistance below 10k ohms on any of the circuits?

Yes


No
  • Go To4

4.CHECK THE (C139) SECOND ROW MODE DOOR DRIVER CIRCUIT FOR A SHORT TO THE (C255) LEFT BLEND DOOR DRIVER CIRCUIT, (C55) LEFT BLEND DOOR COMMON DRIVER CIRCUIT, (C268) RECIRCULATION DOOR DRIVER CIRCUIT, & THE (C68) RECIRCULATION DOOR COMMON DRIVER CIRCUIT





Is the resistance below 10k ohms on any of the circuits?

Yes


No
  • Go To5

5.CHECK THE (C939) SECOND ROW MODE DOOR COMMON DRIVER CIRCUIT FOR A SHORT TO THE (C255) LEFT BLEND DOOR DRIVER CIRCUIT, (C55) LEFT BLEND DOOR COMMON DRIVER CIRCUIT, (C268) RECIRCULATION DOOR DRIVER CIRCUIT, & THE (C68) RECIRCULATION DOOR COMMON DRIVER CIRCUIT





Is the resistance below 10k ohms on any of the circuits?

Yes


No
  • Go To6

6.CHECK THE (C255) LEFT BLEND DOOR DRIVER CIRCUIT FOR A SHORT TO THE (C268) RECIRCULATION DOOR DRIVER CIRCUIT & THE (C68) RECIRCULATION DOOR COMMON DRIVER CIRCUIT





Is the resistance below 10k ohms on any of the circuits?

Yes


No
  • Go To7

7.CHECK THE (C55) LEFT BLEND DOOR COMMON DRIVER CIRCUIT FOR A SHORT TO THE (C268) RECIRCULATION DOOR DRIVER CIRCUIT & THE (C68) RECIRCULATION DOOR COMMON DRIVER CIRCUIT





Is the resistance below 10k ohms on any of the circuits?

Yes


No
  • Go To8

8.CHECK THE FRONT MODE DOOR ACTUATOR CIRCUIT RESISTANCE





Is the resistance below 30.0 ohms?

Yes
  • Go To9


No

9.CHECK THE (C66) FRONT MODE DOOR COMMON DRIVER CIRCUIT FOR A SHORT TO THE (C266) FRONT MODE DOOR DRIVER CIRCUIT






Is the resistance below 10k ohms?

Yes


No

10.CHECK THE SECOND ROW MODE DOOR ACTUATOR CIRCUIT RESISTANCE





Is the resistance below 30.0 ohms?

Yes


No

11.CHECK THE (C939) SECOND ROW MODE DOOR COMMON DRIVER CIRCUIT FOR A SHORT TO THE (C139) SECOND ROW MODE DOOR DRIVER CIRCUIT






Is the resistance below 10k ohms?

Yes


No

12.CHECK THE LEFT BLEND DOOR ACTUATOR CIRCUIT RESISTANCE





Is the resistance below 30.0 ohms?

Yes


No

13.CHECK THE (C55) LEFT BLEND DOOR COMMON DRIVER CIRCUIT FOR A SHORT TO THE (C255) LEFT BLEND DOOR DRIVER CIRCUIT






Is the resistance below 10k ohms?

Yes


No

14.CHECK THE RECIRCULATION DOOR ACTUATOR CIRCUIT RESISTANCE





Is the resistance below 30.0 ohms?

Yes


No

15.CHECK THE (C68) RECIRCULATION DOOR COMMON DRIVER CIRCUIT FOR A SHORT TO THE (C268) RECIRCULATION DOOR DRIVER CIRCUIT






Is the resistance below 10k ohms?

Yes


No

16.VERIFY THAT THE FAULT IS STILL PRESENT




  • Turn the blower control on.
  • Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately 5 seconds) and then release the A/C mode switch.
  • When the A/C status indicator begins displaying DTCs, set the Mode switch to the floor position, simultaneously press the A/C mode switch and the EBL mode switch down until both LEDs start flashing (approximately 5 seconds) and then release the mode switches. Stored DTCs will clear from memory in approximately two seconds.


  • Turn the blower control off.
  • Press and hold the EBL mode switch down and then turn the blower control on. Continue to hold the EBL mode switch down until the EBL status indicator begins flashing. Then, release the EBL mode switch. While the test / function is running, the EBL status indicator will flash once per second. If the test / function passes, the EBL status indicator will stop flashing. If the test / function fails, the A/C and EBL status indicators will flash alternately. Allow the test / function to run to completion before proceeding.

  • Turn the blower control on.
  • Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately 5 seconds) and then release the A/C mode switch.

NOTE: The A/C status indicator displays active DTCs when the EBL status indicator is not illuminated and stored DTCs when the EBL status indicator is illuminated.




Does the A/C status indicator display DTC 42?

Yes


No
  • Using the wiring diagram as a guide, inspect the wiring and connectors for conditions causing an intermittent short that set the original fault. Repair as necessary. Then, if present, diagnose and repair all other DTCs. Refer to the Table of Contents in this Section for a complete list of HVAC related symptoms.
  • Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE).