B1032–EVAPORATOR FIN TEMPERATURE SENSOR CIRCUIT HIGH (ATC)





For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    With the ignition on.

  • Set Condition:

    If the Evaporator Temperature Sensor input is out of range toward the high voltage threshold.


Possible Causes
 
(C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT SHORTED TO VOLTAGE
 
(C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT OPEN
 
(C121) SENSOR GROUND CIRCUIT OPEN
 
EVAPORATOR TEMPERATURE SENSOR
 
A/C HEATER CONTROL
 


NOTE: This DTC must be active for the results of this test to be valid. Do not perform this test if this DTC is stored. Refer to HVAC System Test (ATC) for stored DTC test procedures.



Diagnostic Test

1.CHECK (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT FOR A SHORT TO VOLTAGE








Is the voltage above 0.2 volts?

Yes


No
  • Go To 2

2.CHECK (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT, (C121) SENSOR GROUND CIRCUIT, & EVAPORATOR TEMPERATURE SENSOR




  • 1468 ohms @ 40°C (104°F)
  • 1800 ohms @ 35°C (95°F)
  • 2221 ohms @ 30°C (86°F)
  • 2757 ohms @ 25°C (77°F)
  • 3443 ohms @ 20°C (68°F)
  • 4330 ohms @ 15°C (59°F)
  • 5485 ohms @ 10°C (50°F)
  • 6998 ohms @ 5°C (41°F)
  • 7354 ohms @ 4°C (39°F)
  • 7731 ohms @ 3°C (37°F)
  • 8130 ohms @ 2°C (36°F)
  • 8553 ohms @ 1°C (34°F)
  • 9000 ohms @ 0°C (32°F)


Is the resistance within the specifications?

Yes


No
  • Go To 3

3.CHECK (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT FOR AN OPEN






Is the resistance below 5.0 ohms?

Yes
  • Go To 4


No

4.CHECK (C121) SENSOR GROUND CIRCUIT FOR AN OPEN





Is the resistance below 5.0 ohms?

Yes


No