B210D-BATTERY VOLTAGE LOW

For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    With the ignition on.

  • Set Condition:

    Battery voltage less than 9 volts for more than 15 seconds.


Possible Causes
 
RESISTANCE IN THE (A1) BATTERY POSITIVE CIRCUIT
 
RESISTANCE IN THE GENERATOR CASE GROUND
 
GENERATOR OPERATION
 
GENERATOR FIELD CONTROL CIRCUIT OPEN
 
GENERATOR FIELD CONTROL CIRCUIT SHORTED TO GROUND
 
GROUND CIRCUIT OPEN
 
PCM
 




Diagnostic Test

1.CHECK FOR ANY POWERTRAIN CONTROL MODULES DTCS

NOTE: Make sure the Battery is in good condition. Using the Midtronics Battery Tester, test the Battery before continuing.


NOTE: Inspect the vehicle for after market accessories that may exceed the Generator System output.


NOTE: Make sure the generator drive belt is in good operating condition.


NOTE: Inspect the fuses in the IPM. If an open fuse is found, use the wire diagram/schematic as a guide, inspect the wiring and connectors for damage.





Does the scan tool display any active PCM DTC's?

Yes


No
  • Check the above conditions that can cause a low voltage condition. Repair as necessary.