B1468-CHANNEL 2 AUDIO SPEAKER OUTPUT CIRCUIT OPEN





For a complete wiring diagram Refer to Section 8W.


  • When Monitored:
  • Amplifier Bus wake-up. Amplifier reset with scan tool.
  • Set Condition:
  • The Amplifier detects an open condition on the speaker output circuit.

Possible Causes
 
(X208) AMPLIFIED RIGHT I/P SPEAKER (+) CIRCUIT OPEN
 
(X298) AMPLIFIED RIGHT I/P SPEAKER (-) CIRCUIT OPEN
 
RIGHT I/P SPEAKER
 
AMPLIFIER
 




Diagnostic Test

1.CHECK FOR AN INTERMITTENT CONDITION







Does the scan tool display active: B1468-CHANNEL 2 AUDIO SPEAKER OUTPUT CIRCUIT OPEN?

Yes
  • Go To 2


No
  • The conditions that caused this code to set are not present at this time. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
  • Perform BODY VERIFICATION TEST VER-1.

2.CHECK THE OPERATION OF THE RIGHT FRONT I/P SPEAKER







Is the voltage present greater than 1 volt?

Yes
  • Replace the Amplified Right I/P Speaker in accordance with the service information.
  • Perform BODY VERIFICATION TEST VER-1.


No
  • Go To 3

3.CHECK THE (X208) AMPLIFIED RIGHT I/P SPEAKER (+) CIRCUIT FOR AN OPEN







Is the resistance below 5.0 ohms?

Yes
  • Go To 4


No
  • Repair the (X208) Amplified Right I/P Speaker (+) circuit for an open.
  • Perform BODY VERIFICATION TEST VER-1.

4.CHECK THE (X298) AMPLIFIED RIGHT I/P SPEAKER (-) CIRCUIT FOR AN OPEN







Is the resistance below 5.0 ohms?

Yes
  • Replace the Amplifier in accordance with the service information.
  • Perform BODY VERIFICATION TEST VER-1.


No
  • Repair the (X298) Amplified Right I/P Speaker (-) circuit for an open.