B10B2–A/C COOL DOWN TEST PERFORMANCE (ATC)

For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    When the Cooldown Test is executed.

  • Set Condition:

    If the A/C system is unable to lower the evaporator temperature 11.11°C (20°F) within two minutes.


Possible Causes
 
PREREQUISITES NOT MET BEFORE RUNNING THE TEST
 
ANOTHER RELATED SYSTEM NOT FUNCTIONING CORRECTLY
 
POWERTRAIN SYSTEM FAULTS PRESENT
 




Diagnostic Test

1.VERIFY THAT ALL OF THE COOLDOWN TEST PREREQUISITES WERE MET


  • DTCs B1031 and B1032 must not be active.
  • The refrigerant system must be adequately charged.
  • The blower motor must operate correctly in all speeds.
  • The work area ambient temperature must be above 18.3°C (65°F).
  • The evaporator temperature must be above 18.3°C (65°F).
  • The A/C compressor must be turned off.


Were all of the prerequisites met before running the Cooldown Test?

Yes
  • Go To 2


No

2.CHECK FOR DTCs IN THE PCM



Are any DTCs present in the PCM?

Yes


No