B10EE-CONDENSOR FAN CONTROL CIRCUIT OVERCURRENT (TIPM)

For a complete wiring diagram Refer to Section 8W


  • When Monitored:

    With the ignition on.

  • Set Condition:

    The Totally Integrated Power Module (TIPM) will set this DTC if it detects an overcurrent condition on the (N112) High Speed Radiator Fan Control circuit for more than 500 ms when Radiator Fan operation is requested.


Possible Causes
 
BLOCKAGE STALLING RADIATOR FAN
 
RADIATOR FAN
 
TIPM
 




Diagnostic Test

1.






Does the scan tool display active: B10EE-CONDENSER FAN CONTROL CIRCUIT OVERCURRENT?

Yes
  • Go To2


No
  • The condition that caused this symptom is currently not present. Check for an intermittent condition by inspecting the related wiring harness for chafed, pierced, pinched, and partially broken wires. Also, inspect the related connectors for broken, bent, pushed out, spread, corroded, or contaminated terminals. Repair as necessary.
  • Perform the BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE).

2.




Does the Radiator Fan operate normally?

Yes
  • Go To4


No
  • Go To3

3.







Does the scan tool display active: B10BE–CONDENSER FAN CONTROL CIRCUIT LOW?

Yes


No
  • Go To4

4.







Does the volt meter read 12 volts?

Yes
  • Go To5


No
  • Go To6

5.




Is anything physically preventing Blower Motor operation?

Yes
  • Repair as necessary. Also, check the Radiator Fan for proper operation. Reinstall or replace the Radiator Fan as necessary in accordance with the service information.


No

6.




Is any wire chafing present?

Yes


No