OPERATION
The blower motor is used to control the velocity of air moving through the HVAC housing by spinning the blower wheel within the HVAC air inlet housing at the selected speed.
The blower motor will operate whenever the ignition switch is in the On position and the A/C-heater controls in any position except Off. The blower motor receives fused battery circuit through a fuse and a relay located in the power distribution center (PDC) whenever the ignition switch is in the On position.
Blower motor speed is controlled by regulating the ground path through or around the blower motor resistor and through the blower motor control located within the A/C-heater control.
The blower motor and blower motor wheel are factory balanced as an assembly and cannot be adjusted or repaired and must be replaced if found inoperative or damaged.