P060B-ETC A/D GROUND PERFORMANCE

For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    When the Throttle Motor is powered.

  • Set Condition:

    When A2D reading does not return to ground within a set period of time of test activation, this fault sets. The test typically runs a couple of times per second, and is the reason why APP2 signal spikes to ground a couple of times per second in normal running. Reprogramming the module may not always fix this fault. One trip fault. ETC lamp is illuminated.


Possible Causes
 
PCM NEEDS TO BE PROGRAMMED
 
PCM
 


Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. (Refer to 9 - ENGINE - DIAGNOSIS AND TESTING).



Diagnostic Test

1.PROGRAM THE POWERTRAIN CONTROL MODULE


NOTE: An intermittent loss of power to the PCM without performing an ETC Relearn procedure may cause this DTC to set.


NOTE: Diagnose any other DTCs that may have set with the P060B.








Does this DTC reset by itself?

Yes


No
  • Test Complete.