P0344-CAMSHAFT POSITION SENSOR INTERMITTENT OR MISSING SIGNAL





For a complete wiring diagram Refer to Section 8W


  • When Monitored:

    With the engine speed between 20 and 6000 rpm.

  • Set Condition:

    The ECM does not receive a Camshaft Position Sensor signal.


Possible Causes
 
5-VOLT SUPPLY CIRCUIT OPEN
 
CAMSHAFT POSITION SENSOR SIGNAL CIRCUIT SHORTED TO VOLTAGE
 
CHECKING 5-VOLT SUPPLY CIRCUIT
 
DAMAGED CMP SENSOR OR CAMSHAFT
 
ECM
 
ECM
 
ECM - CAMSHAFT POSITION SENSOR SIGNAL CIRCUIT SHORTED TO VOLTAGE
 
SENSOR GROUND CIRCUIT OPEN
 
INTERMITTENT CONDITION
 
CMP SENSOR SIGNAL CIRCUIT OPEN
 
5-VOLT SUPPLY CIRCUIT SHORTED TO GROUND
 
CMP SENSOR SIGNAL CIRCUIT SHORTED TO GROUND
 
CMASHAFT POSITION SENSOR
 
ECM SENSOR GROUND CIRCUIT OPEN
 
5-VOLT SUPPLY CIRCUIT SHORTED TO THE SENSOR GROUND CIRCUIT
 
CMP SENSOR SIGNAL CIRCUIT SHORTED TO THE SENSOR GROUND CIRCUIT
 




Diagnostic Test

1.VERIFY ACTIVE DTC

NOTE: If DTC P0641, P0651 or P0697 is present with this DTC, diagnose DTCs P0641, P0651 or P0697 before diagnosing this DTC.


NOTE: The Timing Belt/Chain must be correctly installed and operational before diagnosis can be made. Refer to the Service Information to ensure the timing belt is properly installed.


NOTE: If the ECM detects and stores a DTC, the ECM also stores the engine/vehicle operating conditions under which the DTC was set. Some of these conditions are displayed on the scan tool at the same time the DTC is displayed.


NOTE: Before erasing stored DTCs, record these conditions. Attempting to duplicate these conditions may assist when checking for an active DTC.







Does the scan tool display this DTC?

Yes
  • Go To3


No
  • Go To2

2.TEST DRIVE






Does the scan tool display this DTC?

Yes
  • Go To3


No

3.CHECKING CAMSHAFT POSITION SENSOR SIGNAL CKT








Select the appropriate voltage reading.

Voltage is above 5.4 volts.
  • Go To4


Voltage is between 4.7 and 5.4 volts.
  • Go To5


Voltage is below 4.7 volts.

4.CAMSHAFT POSITION SENSOR SIGNAL CIRCUIT SHORT TO VOLTAGE










Is the voltage below 1.0 volt?

Yes


No

5.CHECKING 5-VOLT SUPPLY CIRCUIT





Select the appropriate voltage reading.

Voltage is above 5.4 volts.


Voltage is between 4.7 and 5.4 volts.
  • Go To6


Voltage is below 4.7 volts.

6.SENSOR GND CKT OPEN







Is the resistance below 10.0 ohms?

Yes
  • Go To7


No

7.ECM - SENSOR GROUND CIRCUIT OPEN










Is the voltage below 0.5 volt?

Yes
  • Go To8


No

8.DAMAGED CMP SENSOR OR CAMSHAFT






Is there any evidence of these conditions?

Yes


No
  • Go To9

9.CAMSHAFT POSITION SENSOR




NOTE: The lab scope should display a digital signal (square wave) similar to that shown in Charts and Graphs.



Does the lab scope display an uninterrupted digital signal (square wave)?

Yes


No

10.5-VOLT SUPPLY CIRCUIT OPEN







Is the resistance below 10.0 ohms?

Yes


No

11.5-VOLT SUPPLY CIRCUIT SHORTED TO GROUND








Is the resistance above 1000 ohms?

Yes


No

12.5-VOLT SUPPLY CIRCUIT SHORTED TO THE SENSOR GROUND CIRCUIT








Is the resistance above 1000 ohms?

Yes


No

13.CMP SENSOR SIGNAL CIRCUIT OPEN








Is the resistance below 10.0 ohms?

Yes


No

14.CMP SENSOR SIGNAL CIRCUIT SHORTED TO GROUND








Is the resistance below 1000 ohms?

Yes


No

15.CMP SENSOR SIGNAL CIRCUIT SHORTED TO THE SENSOR GROUND CIRCUIT








Is the resistance below 1000 ohms?

Yes


No