DOOR LOCK RELAY CONTROL CIRCUIT SHORT TO VOLTAGE





For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    With ignition on.

  • Set Condition:

    The BCM detects a high circuit on the Door Lock Relay Control circuit when it is attempting to lock the doors for more than 5 seconds. If the BCM is not able to ground its side of the relay coil, the control circuit remains high.


Possible Causes
 
RELAY SHORTED
 
JUNCTION BLOCK - DOOR LOCK RELAY CONTROL SHORT TO VOLTAGE
 
BODY CONTROL MODULE - SHORTED
 




Diagnostic Test

1.CHECK TROUBLE CODE

NOTE: If the door locks are totally inoperative, check fuse No. 6 before proceeding.







Does the scan tool display DOOR LOCK RELAY CONTROL CIRCUIT SHORT TO VOLTAGE?

Yes
  • Go To2


No

2.CHECK FOR SHORTED RELAY











Does the scan tool display DOOR LOCK RELAY CONTROL CIRCUIT SHORT TO VOLTAGE?

Yes
  • Go To3


No

3.CHECK THE JUNCTION BLOCK FOR THE DOOR LOCK RELAY CONTROL CIRCUIT SHORT TO VOLTAGE






NOTE: Ensure the Junction Block connectors are reconnected at this time.





Is there any voltage present?

Yes


No