*FLIP-UP GLASS AJAR CIRCUIT SHORT TO GROUND





For a complete wiring diagram Refer to Section 8W.

Theory of Operation


The scan tool will display the door state NOT the switch state. It will display as True/False. True states that the door is ajar (open). False states that the door is NOT ajar (closed).



Possible Causes
 
(G80) FLIP-UP GLASS AJAR SWITCH SENSE CIRCUIT SHORT TO GROUND
 
FLIP-UP GLASS AJAR SWITCH
 
BODY CONTROL MODULE
 



1.CHECK FOR SHORTED FLIP-UP GLASS AJAR SWITCH






Does the scan tool display FLIP-UP AJAR SW: FALSE?

Yes


No
  • Go To2

2.






Does the test light illuminate brightly?

No


Yes