B17B9–RIGHT STOP LAMP CONTROL CIRCUIT OVERCURRENT

For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    Continuously.

  • Set Condition:

    When the Totally Integrated Power Module (TIPM) detects a OVERCURRENT condition.


Possible Causes
 
(L54) RIGHT STOP LAMP CONTROL CIRCUIT SHORT TO GROUND
 
(L54) RIGHT STOP LAMP CONTROL CIRCUIT SHORTED TO VOLTAGE
 
TOTALLY INTEGRATED POWER MODULE
 




Diagnostic Test

1.TEST FOR INTERMITTENT CONDITION






Does the scan tool display active: B17B9–RIGHT STOP LAMP CONTROL CIRCUIT OVERCURRENT?

Yes
  • Go To 2


No
  • The condition that caused this symptom is currently not present. Check for an intermittent condition by inspecting the related wiring harness for chafed, pierced, pinched, and partially broken wires. Also, inspect the related connectors for broken, bent, pushed out, spread, corroded, or contaminated terminals. Repair as necessary.
  • Perform the BODY VERIFICATION TEST - VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE)

2.RIGHT STOP LAMP BULB





Is the inoperative bulb OK?

Yes
  • Go To 3


No

3.(L54) RIGHT STOP LAMP CONTROL CIRCUIT SHORT TO GROUND





Is the resistance above 10k ohms?

Yes
  • Go To 4


No

4.(L54) RIGHT STOP LAMP CONTROL CIRCUIT SHORTED TO VOLTAGE




Is there any voltage present?

Yes


No