B183A–PASSENGER DOORS UNLOCK CONTROL CIRCUIT HIGH– CLUSTER





For a complete wiring diagram Refer to Section 8W.


  • When Monitored:

    Continuously

  • Set Condition:

    When the Cluster senses a high condition on the (P292) Door Unlock Relay Control circuit for over 10 seconds, this code will set.


Possible Causes
 
(P292) DOOR UNLOCK RELAY CONTROL CIRCUIT SHORT TO BATTERY
 
JUNCTION BLOCK
 
INSTRUMENT CLUSTER
 




Diagnostic Test

1.TEST FOR INTERMITTENT CONDITION







Does the scan tool display B183A-PASSENGER DOORS UNLOCK CONTROL CIRCUIT HIGH?

Yes
  • Go To 2


No

2.DOOR UNLOCK RELAY SHORTED TO BATTERY


NOTE: Ensure the windows are down before proceeding.







Did the doors unlock?

Yes


No
  • Go To 3

3.(P292) DOOR UNLOCK RELAY CONTROL CIRCUIT SHORTED TO BATTERY







Is there any voltage present?

Yes


No